LS Mecapion L7P INDEXER Series Error AL15: Current offset

AC servo · taken from the manufacturer’s manual, pages cited

Error codeAL15

Motor U/V/W phase current offset oversetting The manual's first action is: “Check whether the U/V/W phase current offset [0x2015~0x2017] are 5% of the rated current or highter.”

Model
LS Mecapion L7P INDEXER Series
Display shows
Current offset (AL15)
Type
Error code
Source
Manual p. 269

What AL15 means

Current offset p. 269

Common causes

  • Motor U/V/W phase current offset oversetting p. 269

What to do

  1. Check whether the U/V/W phase current offset [0x2015~0x2017] are 5% of the rated current or highter. p. 269

If AL15 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact LS Mecapion service.

This page summarises what the manufacturer’s manual says about AL15; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with LS Mecapion. Found a mistake? Report an error.