Error codeErr05
Err05 indicates acceleration overvoltage due to input voltage too high, external force dragging the motor during acceleration, or acceleration time too short. The manual lists no action for this code.
- Model
- Inovance MD380M
- Display shows
- Acceleration Overvoltage (Err05)
- Type
- Error code
- Source
- Manual p. 213
What Err05 means
Acceleration Overvoltage p. 213
Common causes
- 1. Input voltage too high p. 213
- 2. External force dragging the motor during acceleration p. 213
- 3. Acceleration time too short p. 213
- 4. No brake unit or brake resistor installed p. 213
- 1. Adjust voltage to normal range p. 213
- 2. Remove external force or install brake resistor p. 213
- 3. Increase acceleration time p. 213
- 4. Install brake unit and resistor p. 213
If Err05 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.
This page summarises what the manufacturer’s manual says about Err05; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.