Inovance MD380M Error Err05: Acceleration Overvoltage

Inovance MD380M Servo Driver · taken from the manufacturer’s manual, pages cited

Error codeErr05

Err05 indicates acceleration overvoltage due to input voltage too high, external force dragging the motor during acceleration, or acceleration time too short. The manual lists no action for this code.

Model
Inovance MD380M
Display shows
Acceleration Overvoltage (Err05)
Type
Error code
Source
Manual p. 213

What Err05 means

Acceleration Overvoltage p. 213

Common causes

  • 1. Input voltage too high p. 213
  • 2. External force dragging the motor during acceleration p. 213
  • 3. Acceleration time too short p. 213
  • 4. No brake unit or brake resistor installed p. 213
  • 1. Adjust voltage to normal range p. 213
  • 2. Remove external force or install brake resistor p. 213
  • 3. Increase acceleration time p. 213
  • 4. Install brake unit and resistor p. 213

If Err05 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.

This page summarises what the manufacturer’s manual says about Err05; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.