Err02 indicates acceleration overcurrent due to a ground fault or short circuit in the servo drive output circuit, vector control mode selected without performing parameter identification, or acceleration time too short. The manual lists no action for this code.
- Model
- Inovance MD380M
- Display shows
- Acceleration Overcurrent (Err02)
- Type
- Fault code
- Source
- Manual p. 212
What Err02 means
Acceleration Overcurrent p. 212
Common causes
- 1. Ground fault or short circuit in the servo drive output circuit p. 212
- 2. Vector control mode selected without performing parameter identification p. 212
- 3. Acceleration time too short p. 212
- 4. Manual torque boost or inappropriate VF curve p. 212
- 5. Low voltage p. 212
- 6. Starting a motor that is already rotating p. 212
- 7. Sudden load addition during acceleration p. 212
- 8. Servo drive undersized for the application p. 212
If Err02 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.
This page summarises what the manufacturer’s manual says about Err02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.