Inovance MD380M Error Err02: Acceleration Overcurrent

Inovance MD380M Servo Driver · taken from the manufacturer’s manual, pages cited

Fault codeErr02

Err02 indicates acceleration overcurrent due to a ground fault or short circuit in the servo drive output circuit, vector control mode selected without performing parameter identification, or acceleration time too short. The manual lists no action for this code.

Model
Inovance MD380M
Display shows
Acceleration Overcurrent (Err02)
Type
Fault code
Source
Manual p. 212

What Err02 means

Acceleration Overcurrent p. 212

Common causes

  • 1. Ground fault or short circuit in the servo drive output circuit p. 212
  • 2. Vector control mode selected without performing parameter identification p. 212
  • 3. Acceleration time too short p. 212
  • 4. Manual torque boost or inappropriate VF curve p. 212
  • 5. Low voltage p. 212
  • 6. Starting a motor that is already rotating p. 212
  • 7. Sudden load addition during acceleration p. 212
  • 8. Servo drive undersized for the application p. 212

If Err02 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.

This page summarises what the manufacturer’s manual says about Err02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.