Err03 indicates deceleration overcurrent due to a ground fault or short circuit in the servo drive output circuit, vector control mode selected without parameter identification, or deceleration time too short. The manual lists no action for this code.
- Model
- Inovance MD380M
- Display shows
- Deceleration Overcurrent (Err03)
- Type
- Fault code
- Source
- Manual p. 213
What Err03 means
Deceleration Overcurrent p. 213
Common causes
- 1. Ground fault or short circuit in the servo drive output circuit p. 213
- 2. Vector control mode selected without parameter identification p. 213
- 3. Deceleration time too short p. 213
- 4. Low voltage p. 213
- 5. Sudden load addition during deceleration p. 213
- 6. No brake unit or brake resistor installed p. 213
- 1. Eliminate external faults p. 213
- 2. Perform motor parameter identification p. 213
- 3. Increase deceleration time p. 213
- 4. Adjust voltage to normal range p. 213
- 5. Remove superimposed load p. 213
- 6. Install brake unit and resistor p. 213
If Err03 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.
This page summarises what the manufacturer’s manual says about Err03; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.