Err13 indicates output phase loss due to wiring from servo drive to motor being abnormal, motor running time with unbalanced three-phase output from servo drive, or drive board fault. The manual's first action is: “1. Eliminate external faults”
- Model
- Inovance MD380M
- Display shows
- Output Phase Loss (Err13)
- Type
- Fault code
- Source
- Manual p. 215
What Err13 means
Output Phase Loss p. 215
Common causes
- 1. Wiring from servo drive to motor is abnormal p. 215
- 2. Motor running time with unbalanced three-phase output from servo drive p. 215
- 3. Drive board fault p. 215
- 4. Module fault p. 215
What to do
- 1. Eliminate external faults p. 215
- 2. Check motor three-phase windings for normal operation and clear any faults p. 215
Before you service the product, read the safety instructions in the manual p. 8.
If Err13 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.
This page summarises what the manufacturer’s manual says about Err13; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.