GSK GSK980TB3 Error 189: Chuck in-position signal is not received within the stipulated time.

GSK GSK980TB3 · taken from the manufacturer’s manual, pages cited

Alarm code189

The system did not receive a signal that the chuck is in position within the allowed time. The manual's first action is: “Check whether the wire of external alarm is correct. Adjust parameter P91 arrival time or modify parameter NO.15 Bit2 to 0: Shield chuck in-position.”

Model
GSK GSK980TB3
Display shows
189
Type
Alarm code
Source
Manual p. 271

What 189 means

Chuck in-position signal is not received within the stipulated time. p. 271

Common causes

  • Chuck in-position detection is active. p. 271

What to do

  1. Check whether the wire of external alarm is correct. Adjust parameter P91 arrival time or modify parameter NO.15 Bit2 to 0: Shield chuck in-position. p. 271

If 189 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.

This page summarises what the manufacturer’s manual says about 189; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GSK. Found a mistake? Report an error.