The system did not receive a signal that the chuck is in position within the allowed time. The manual's first action is: “Check whether the wire of external alarm is correct. Adjust parameter P91 arrival time or modify parameter NO.15 Bit2 to 0: Shield chuck in-position.”
- Model
- GSK GSK980TB3
- Display shows
- 189
- Type
- Alarm code
- Source
- Manual p. 271
What 189 means
Chuck in-position signal is not received within the stipulated time. p. 271
Common causes
- Chuck in-position detection is active. p. 271
What to do
- Check whether the wire of external alarm is correct. Adjust parameter P91 arrival time or modify parameter NO.15 Bit2 to 0: Shield chuck in-position. p. 271
If 189 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact GSK service.