Error code65
IPM error / Trip terminal I error indicates abnormal current at the IPM due to blocked heat radiation. The manual's first action is: “-Check connections of outdoor unit electrical components.”
- Model
- Fujitsu General 410A
- Display shows
- IPM error / Trip terminal I error (65)
- Type
- Error code
- Source
- Manual p. 5
What 65 means
IPM error / Trip terminal I error p. 5
Common causes
- Abnormal current value at the IPM is detected. Heat radiation is blocked (inlet/outlet). p. 5
- -IPM Error - Abnormal current value at the IPM is detected. Heat radiation is blocked (inlet/outlet). p. 5
- -Check outdoor fan, heat exchanger. p. 5
What to do
- -Check connections of outdoor unit electrical components. p. 5
- -Check compressor resistance values. (Ref. Service Tip #010-AC TPM Check and/or "AC TPM Error" under "Troubleshooting by Error Code" Type In Zendesk Help Center.) p. 5
- -Ref. Service Tip #008-Fan Motor Check p. 5
If 65 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujitsu General service.
This page summarises what the manufacturer’s manual says about 65; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujitsu General. Found a mistake? Report an error.