Fujitsu General 410A Error 65: IPM error / Trip terminal I error

Fujitsu General 410A · taken from the manufacturer’s manual, pages cited

Error code65

IPM error / Trip terminal I error indicates abnormal current at the IPM due to blocked heat radiation. The manual's first action is: “-Check connections of outdoor unit electrical components.”

Model
Fujitsu General 410A
Display shows
IPM error / Trip terminal I error (65)
Type
Error code
Source
Manual p. 5

What 65 means

IPM error / Trip terminal I error p. 5

Common causes

  • Abnormal current value at the IPM is detected. Heat radiation is blocked (inlet/outlet). p. 5
  • -IPM Error - Abnormal current value at the IPM is detected. Heat radiation is blocked (inlet/outlet). p. 5
  • -Check outdoor fan, heat exchanger. p. 5

What to do

  1. -Check connections of outdoor unit electrical components. p. 5
  2. -Check compressor resistance values. (Ref. Service Tip #010-AC TPM Check and/or "AC TPM Error" under "Troubleshooting by Error Code" Type In Zendesk Help Center.) p. 5
  3. -Ref. Service Tip #008-Fan Motor Check p. 5

If 65 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujitsu General service.

This page summarises what the manufacturer’s manual says about 65; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujitsu General. Found a mistake? Report an error.