Error code77
Heat sink thermistor error indicates the heat sink temperature thermistor is open or shorted. The manual's first action is: “-Check for erroneous connection or removed connector.”
- Model
- Fujitsu General 410A
- Display shows
- Heat sink thermistor error (77)
- Type
- Error code
- Source
- Manual p. 5
What 77 means
Heat sink thermistor error p. 5
Common causes
- When heat-sink temperature thermistor is open or a short-circuit is detected at power up or while running the compressor. p. 5
What to do
- -Check for erroneous connection or removed connector. p. 5
- -Check resistance of thermistor. (Ref. Thermistor Resistance Chart) p. 5
If 77 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujitsu General service.
This page summarises what the manufacturer’s manual says about 77; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujitsu General. Found a mistake? Report an error.