Error code51
Indoor unit fan motor error code 51 indicates the fan's actual frequency is below one-third of its target for more than 56 seconds. The manual's first action is: “Check rotation of fan.”
- Model
- Fujitsu General 410A
- Display shows
- Indoor unit fan motor error (51)
- Type
- Error code
- Source
- Manual p. 4
What 51 means
Indoor unit fan motor error p. 4
Common causes
- -Check ambient temperature around motor. p. 4
- -Check indoor unit fan motor resistance values. p. 4
- -Indoor Unit Fan Motor Error - When the condition that actual frequency of indoor fan is below 1/3 of target frequency is continued more than 56 seconds. p. 4
- -Replace controller PCB. p. 4
- When the condition that actual frequency of indoor fan is below 1/3 of target frequency is continued more than 56 seconds. p. 4
What to do
- Check rotation of fan. p. 4
- (Ref. Service Tip #008-Fan Motor Check and/or "Fan Motor Check" in Zendesk Help Center) p. 4
- -Check rotation of fan. p. 4
- -Check indoor unit fan motor resistance values. p. 4
- -Ref. Service Tip #008-Fan Motor Check and/or "Fan Motor Check" under "Troubleshooting by Error Code" type in Zendesk Help Center. p. 4
- -Replace controller PCB. (Ref. Service Tip #008-Fan Motor Check and/or "Fan Motor Check" under "Troubleshooting by Error Code" Type In Zendesk Help Center) p. 4
If 51 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujitsu General service.
This page summarises what the manufacturer’s manual says about 51; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujitsu General. Found a mistake? Report an error.