Check run unfinished when remote command is input without confirming completion. The manual's first action is: “Check indoor unit number connection. - Power down all indoor units with remote controller, reset dis connect and branch box power for 5 minutes, reinitiate check run operation.”
- Model
- Fujitsu General 410A
- Display shows
- Check run unfinished (1)
- Type
- Error code
- Source
- Manual p. 13
What 1 means
Check run unfinished p. 13
Common causes
- When the operation command is inputted by the remote controller without check operation completion. p. 13
- Primary unit: LED401 is lit. p. 13
What to do
- Check indoor unit number connection. - Power down all indoor units with remote controller, reset dis connect and branch box power for 5 minutes, reinitiate check run operation. p. 13
If 1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujitsu General service.
This page summarises what the manufacturer’s manual says about 1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujitsu General. Found a mistake? Report an error.