Error code52、53
This code indicates that the synchronization signal (ITP) stopped in communication data with the CNC. The manual's first action is: “(a) SVPM failure – replace the SVPM or its control PCB.”
- Model
- FANUC B-65325CM/01
- Display shows
- 52、53
- Type
- Error code
- Source
- Manual p. 173
What 52、53 means
Synchronization signal (ITP) stopped in communication data with the CNC. p. 173
Common causes
- Synchronization signal (ITP) stopped in communication data with the CNC. p. 173
What to do
- (a) SVPM failure – replace the SVPM or its control PCB. p. 173
- (b) CNC failure – replace the board or module related to the serial spindle. p. 173
Before you service the product, read the safety instructions in the manual p. 3.
If 52、53 is still not resolved
This page summarises what the manufacturer’s manual says about 52、53; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.