After an emergency‑stop signal is input, the motor accelerates instead of decelerating. The manual's first action is: “When the alarm occurs, troubleshooting steps: (a) Speed detector parameter is incorrect. Refer to item 1 of the FANUC AC SPINDLE MOTOR o i/bi series parameter manual (B-65280CM) and set the correct value. (b) The acceleration/deceleration time parameter is unreasonable. Verify that the parameter value matches the actual deceleration time and set a value that provides margin over the actual deceleration time.”
- Model
- FANUC B-65325CM/01
- Display shows
- 37
- Type
- Alarm code
- Source
- Manual p. 170
What 37 means
After an emergency‑stop signal is input, the motor accelerates instead of decelerating. This can also occur after the acceleration/deceleration time (initially set to 10 seconds) has elapsed but the motor field is not cut off (deceleration not completed). p. 170
Common causes
- After an emergency‑stop signal is input, the motor accelerates instead of decelerating. This can also occur after the acceleration/deceleration time (initially set to 10 seconds) has elapsed but the motor field is not cut off (deceleration not completed). p. 170
What to do
- When the alarm occurs, troubleshooting steps: (a) Speed detector parameter is incorrect. Refer to item 1 of the FANUC AC SPINDLE MOTOR o i/bi series parameter manual (B-65280CM) and set the correct value. (b) The acceleration/deceleration time parameter is unreasonable. Verify that the parameter value matches the actual deceleration time and set a value that provides margin over the actual deceleration time. p. 170
Before you service the product, read the safety instructions in the manual p. 3.
If 37 is still not resolved