Error code36
Error counter overflow due to incorrect parameter setting. The manual's first action is: “(a) Gear ratio parameter is incorrect. Verify that the gear ratio data has not been set to an excessively large value.”
- Model
- FANUC B-65325CM/01
- Display shows
- Error counter overflow. (36)
- Type
- Error code
- Source
- Manual p. 170
What 36 means
Error counter overflow. p. 170
Common causes
- Incorrect parameter setting. p. 170
What to do
- (a) Gear ratio parameter is incorrect. Verify that the gear ratio data has not been set to an excessively large value. p. 170
- (b) Position gain setting is incorrect. When the gear ratio data is correct, increase the position gain value. p. 170
Before you service the product, read the safety instructions in the manual p. 3.
If 36 is still not resolved