This manual introduces safety precautions, notes, and operating methods for maintenance of FANUC servo motors, spindle motors, and servo amplifiers.
This manual outlines the safety usage requirements for FANUC AC servo motors, spindle motors and servo amplifiers. It emphasizes reading all warnings, cautions and notes before operation, and details protective measures such as wearing safety gear and avoiding contact with moving parts.
Installation, electrical connection, and maintenance instructions are included, covering proper grounding, key‑required machines, cooling periods, and compliance with standards such as EN60204-1 and IEC60034. The document also specifies temperature limits and the need to use only the designated amplifiers. This manual is written in Japanese.
| Minimum power‑off cooling time | 30 minutes |
|---|---|
| Compliance standard (electrical safety) | EN60204-1 |
| Compliance standard (mechanical safety) | IEC60034 |
The power must remain disconnected for at least 30 minutes before touching the unit.
No, only the specified amplifier and parameters may be used with the machine.