FANUC B-65325CM/01 Error 21: The polarity of the position sensor is incorrect.

FANUC B-65325CM/01 · taken from the manufacturer’s manual, pages cited

Alarm code21

The polarity of the position sensor is incorrect. The manual's first action is: “When the alarm occurs, troubleshooting steps: (a) Verify the position sensor polarity parameter (No.4001#4). (b) Verify the wiring of the position sensor feedback cable.”

Model
FANUC B-65325CM/01
Display shows
The polarity of the position sensor is incorrect. (21)
Type
Alarm code
Source
Manual p. 165

What 21 means

The polarity of the position sensor is incorrect. p. 165

Common causes

  • The polarity of the position sensor is incorrect. p. 165

What to do

  1. When the alarm occurs, troubleshooting steps: (a) Verify the position sensor polarity parameter (No.4001#4). (b) Verify the wiring of the position sensor feedback cable. p. 165

Before you service the product, read the safety instructions in the manual p. 3.

If 21 is still not resolved

  • 请在故障的原因彻底清除之后再进行报警复位操作 p. 15
    “请在故障的原因彻底清除之后再进行报警复位操作”
  • 有关维护方面的疑问事项,请尽早与 FANUC 公司联络 p. 15
    “有关维护方面的疑问事项,请尽早与 FANUC 公司联络”

This page summarises what the manufacturer’s manual says about 21; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FANUC. Found a mistake? Report an error.