Drivecon VFN2 Error STP2: Emergency stop command by STOP key

Adjustable frequency ac motor drive · taken from the manufacturer’s manual, pages cited

Fault codeSTP2

Emergency stop command by STOP key is activated when the STOP key is pressed during operation in remote control mode. The manual's first action is: “Inverter will not restart until Run switch is turned off and then turned on again.”

Model
Drivecon VFN2
Display shows
Emergency stop command by STOP key (STP2)
Type
Fault code
Source
Manual p. 63

What STP2 means

Emergency stop command by STOP key p. 63

Common causes

  • Emergency stop via digital operator in remote control mode (Fn10=1) by pressing STOP key (Fn48=xx0x). Once STOP key is pressed during operation, inverter will stop according to the setting of Fn44 and display STP2. p. 63
  • If inverter is under communication control and Fn48=xx0x, once STOP key is pressed, inverter will stop according to the setting of Fn44 and display STP2. p. 63
  • STOP key can not be used for emergency stop when Fn48=xx1x. p. 63

What to do

  1. Inverter will not restart until Run switch is turned off and then turned on again. p. 63
  2. Inverter will not restart until computer sends Stop command followed by a RUN command. p. 63

If STP2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Drivecon service.

This page summarises what the manufacturer’s manual says about STP2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Drivecon. Found a mistake? Report an error.