Drivecon VFN2 Error Err2: Setting error

Adjustable frequency ac motor drive · taken from the manufacturer’s manual, pages cited

Error codeErr2

Setting error occurs when Fn07 is within an invalid range, Fn06 is less than or equal to Fn07, or Fn70 is less than or equal to Fn75. The manual's first action is: “1. Adjust Fn65-Fn68 or Fn07 setting.”

Model
Drivecon VFN2
Display shows
Setting error (Err2)
Type
Error code
Source
Manual p. 64

What Err2 means

Setting error p. 64

Common causes

  • 1. Fn07 is in the range of Fn65 ± Fn68, Fn66 ± Fn68 or Fn67 ± Fn68. p. 64
  • 2. Fn06< or equal to Fn07. p. 64
  • 3. Fn70 < or equal to Fn75. p. 64
  • 4. Fn27 > or equal to Fn28. p. 64

What to do

  1. 1. Adjust Fn65-Fn68 or Fn07 setting. p. 64
  2. 2. Fn06>Fn07. p. 64
  3. 3. Fn70>Fn75. p. 64
  4. 4. Fn27 p. 64

If Err2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Drivecon service.

This page summarises what the manufacturer’s manual says about Err2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Drivecon. Found a mistake? Report an error.