Drivecon VFN2 Error Err1: Operation error

Adjustable frequency ac motor drive · taken from the manufacturer’s manual, pages cited

Error codeErr1

Operation error occurs when trying to change frequency or parameters during operation under restricted conditions. The manual's first action is: “1. Set Fn11=0.”

Model
Drivecon VFN2
Display shows
Operation error (Err1)
Type
Error code
Source
Manual p. 64

What Err1 means

Operation error p. 64

Common causes

  • 1. Try to change frequency by pressing up or down arrow keys when Fn11>0. p. 64
  • 2. Try to change Fn124. p. 64
  • 3. Try to change functions which cannot be changed during operation. p. 64

What to do

  1. 1. Set Fn11=0. p. 64
  2. 2. Fn124 (CPU version) cannot be changed. p. 64
  3. 3. Change those functions in stop mode. p. 64

If Err1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Drivecon service.

This page summarises what the manufacturer’s manual says about Err1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Drivecon. Found a mistake? Report an error.