Drivecon VFN2 Error OL3: Overtorque.

Adjustable frequency ac motor drive · taken from the manufacturer’s manual, pages cited

Fault codeOL3

Overtorque occurs when the load is too high, the V/F pattern is inappropriate, or the Fn78 and Fn79 settings are too low. The manual's first action is: “1. Select a larger HP inverter. 2. Select optimum V/F pattern 3. Select appropriate Fn78 and Fn79 settings.”

Model
Drivecon VFN2
Display shows
Overtorque. (OL3)
Type
Fault code
Source
Manual p. 62

What OL3 means

Overtorque. p. 62

Common causes

  • 1. Load is too high. 2. Inappropriate V/F pattern selection. 3. Fn78, Fn79 are set too low. p. 62

What to do

  1. 1. Select a larger HP inverter. 2. Select optimum V/F pattern 3. Select appropriate Fn78 and Fn79 settings. p. 62

If OL3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Drivecon service.

This page summarises what the manufacturer’s manual says about OL3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Drivecon. Found a mistake? Report an error.