Error codeErr3

Setting error occurs when the V/F curve is too steep or the analog frequency signal is set too steep. The manual's first action is: “1. (Fn38-Fn40) / (Fn37-Fn39) < or equal to 65.”

Model
Drivecon VFN2
Display shows
Setting error (Err3)
Type
Error code
Source
Manual p. 64

What Err3 means

Setting error p. 64

Common causes

  • 1. V/F curve is set too steep when Fn05=18. p. 64
  • 2. Analog frequency signal is set too steep. p. 64

What to do

  1. 1. (Fn38-Fn40) / (Fn37-Fn39) < or equal to 65. p. 64
  2. 2. (Fn40-Fn41) / (Fn39-0.1) < or equal to 65. p. 64
  3. 2. (Fn06-Fn26) / (Fn28-Fn27) < or equal to 65. p. 64

If Err3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Drivecon service.

This page summarises what the manufacturer’s manual says about Err3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Drivecon. Found a mistake? Report an error.