Delta VFD110CT43F21A3 Error ot1: Over torque 1

Delta VFD110CT43F21A3 · taken from the manufacturer’s manual, pages cited

Alarm codeot1

The ot1 code indicates Over torque 1, where an alarm occurs when the output current exceeds the over-torque detection reference parameters 06-07 or 06-10, and also exceeds the over-torque detection time parameters 06-08 or 06-11. The manual's first action is: “Troubleshooting: Check whether the motor is overloaded; verify that the motor rated current (parameter 05‑01) is appropriate; increase motor capacity.”

Model
Delta VFD110CT43F21A3
Display shows
Over torque 1 (ot1)
Type
Alarm code
Source
Manual p. 299

What ot1 means

Over torque 1 p. 299

Common causes

  • An alarm occurs when the output current exceeds the over‑torque detection reference parameters 06‑07 or 06‑10, and also exceeds the over‑torque detection time parameters 06‑08 or 06‑11, while parameters 06‑06 or 06‑09 are set to 2 or 4. p. 299

What to do

  1. Troubleshooting: Check whether the motor is overloaded; verify that the motor rated current (parameter 05‑01) is appropriate; increase motor capacity. p. 299

Before you service the product, read the safety instructions in the manual p. 291.

If ot1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ot1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.