Delta ASDA-B2 series Error AL011: Encoder fault

Delta ASDA-B2 series · taken from the manufacturer’s manual, pages cited

Fault codeAL011

The encoder fault occurs when the encoder wiring is incorrect, loose, or poorly wired. The manual's first action is: “Confirm wiring follows the manual's recommended wiring; correct wiring”

Model
Delta ASDA-B2 series
Display shows
Encoder fault (AL011)
Type
Fault code
Source
Manual p. 157

What AL011 means

Encoder fault p. 157

Common causes

What to do

  1. Confirm wiring follows the manual's recommended wiring; correct wiring p. 157
  2. Inspect the CN2 connector on the drive and the encoder; reinstall p. 157
  3. Check whether the CN2 connector and the servo motor encoder wiring are loose; reconnect wiring p. 157
  4. Motor fault; replace motor p. 157

Before you service the product, read the safety instructions in the manual p. 122.

If AL011 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL011; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.