Delta ASDA-B2 series Error AL016: IGBT overheat

Delta ASDA-B2 series · taken from the manufacturer’s manual, pages cited

Error codeAL016

AL016 indicates IGBT overheat due to continuous use beyond the drive's rated load or drive output short circuit. The manual's first action is: “Check if load is too large or motor current too high; increase motor capacity or reduce load”

Model
Delta ASDA-B2 series
Display shows
IGBT overheat (AL016)
Type
Error code
Source
Manual p. 158

What AL016 means

IGBT overheat p. 158

Common causes

  • Continuous use beyond the drive's rated load p. 158
  • Drive output short circuit p. 158

What to do

  1. Check if load is too large or motor current too high; increase motor capacity or reduce load p. 158
  2. Inspect drive output wiring; correct wiring p. 158

Before you service the product, read the safety instructions in the manual p. 122.

If AL016 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL016; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.