The overload occurs when the drive is used continuously beyond its rated load, the control system parameters are improperly set, or there is a motor or encoder wiring error. The manual's first action is: “Increase motor capacity or reduce load”
- Model
- Delta ASDA-B2 series
- Display shows
- Overload (AL006)
- Type
- Error code
- Source
- Manual p. 156
What AL006 means
Overload p. 156
Common causes
- Continuous use beyond the drive's rated load p. 156
- Improper control system parameter settings p. 156
- Motor or encoder wiring error p. 156
- Defective motor encoder p. 156
What to do
- Increase motor capacity or reduce load p. 156
- 1. Adjust control loop gain value 2. Slow down acceleration/deceleration setting time p. 156
- Correct wiring p. 156
- Return to dealer or manufacturer for service p. 156
Before you service the product, read the safety instructions in the manual p. 122.
If AL006 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL006; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.