Delta ASDA-B2 series Error AL006: Overload

Delta ASDA-B2 series · taken from the manufacturer’s manual, pages cited

Error codeAL006

The overload occurs when the drive is used continuously beyond its rated load, the control system parameters are improperly set, or there is a motor or encoder wiring error. The manual's first action is: “Increase motor capacity or reduce load”

Model
Delta ASDA-B2 series
Display shows
Overload (AL006)
Type
Error code
Source
Manual p. 156

What AL006 means

Overload p. 156

Common causes

  • Continuous use beyond the drive's rated load p. 156
  • Improper control system parameter settings p. 156
  • Motor or encoder wiring error p. 156
  • Defective motor encoder p. 156

What to do

  1. Increase motor capacity or reduce load p. 156
  2. 1. Adjust control loop gain value 2. Slow down acceleration/deceleration setting time p. 156
  3. Correct wiring p. 156
  4. Return to dealer or manufacturer for service p. 156

Before you service the product, read the safety instructions in the manual p. 122.

If AL006 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL006; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.