Delta ASDA-B2 series Error AL005: Regeneration error

Delta ASDA-B2 series · taken from the manufacturer’s manual, pages cited

Error codeAL005

The regeneration error occurs when the regeneration resistor is not connected or too small, the regeneration switching transistor fails, or the parameter settings are incorrect. The manual's first action is: “Reconnect regeneration resistor or calculate appropriate resistor value”

Model
Delta ASDA-B2 series
Display shows
Regeneration error (AL005)
Type
Error code
Source
Manual p. 156

What AL005 means

Regeneration error p. 156

Common causes

  • Regeneration resistor not connected or too small p. 156
  • Regeneration switching transistor failure p. 156
  • Parameter setting error p. 156

What to do

  1. Reconnect regeneration resistor or calculate appropriate resistor value p. 156
  2. Return to dealer or manufacturer for service p. 156
  3. Reset correctly p. 156

Before you service the product, read the safety instructions in the manual p. 122.

If AL005 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL005; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.