Error codeE805
An exhaust fan (FM2, FM4, FM5) or connector or DC controller PCB is faulty, causing a ventilation error that requires checking service mode '106'. The manual's first action is: “Check service mode '106' (E805 details) while 'E805' is being indicated.”
- Model
- Canon NP7161/NP7160
- Display shows
- E805
- Type
- Error code
- Source
- Manual p. 281
What E805 means
Connector p. 281
Common causes
- Connector p. 281
- Exhaust fan (FM2, FM4, FM5) p. 281
- DC controller PCB p. 281
- The exhaust fan (FM2, FM4) is faulty. p. 281
What to do
- Check service mode '106' (E805 details) while 'E805' is being indicated. p. 281
- Connect the connectors. p. 281
- Replace the exhaust fan. Is the problem corrected? p. 281
- Check the wiring from the DC controller PCB to the exhaust fan; if normal, replace the DC controller PCB. p. 281
- The exhaust fan drive detection signal (EXFAN1_DT*, FXFAN0_DT*) cannot be detected 0.5 sec after the start of the exhaust fan (FM2, FM4). p. 281
If E805 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Canon service.
This page summarises what the manufacturer’s manual says about E805; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Canon. Found a mistake? Report an error.