Error codeE010
A connector, power supply PCB, or main motor (M1) is faulty, causing a failure in the system's basic operation. The manual's first action is: “Connect the connectors.”
- Model
- Canon NP7161/NP7160
- Display shows
- E010
- Type
- Error code
- Source
- Manual p. 275
What E010 means
Connector p. 275
Common causes
- Connector p. 275
- Power supply PCB p. 275
- Main motor (M1) p. 275
- DC controller PCB p. 275
- The main motor (M1) is faulty. p. 275
- The DC controller PCB is faulty. p. 275
What to do
- Connect the connectors. p. 275
- Turn on the power switch. Set the meter range to 30 VDC, and connect the probes to J209-4 (+) and J209-3 (-) on the DC controller PCB. Is the voltage about 24 V? p. 275
- Replace the main motor. Is the problem corrected? p. 275
- Replace the DC controller PCB. p. 275
If E010 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Canon service.
This page summarises what the manufacturer’s manual says about E010; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Canon. Found a mistake? Report an error.