Thermistors (TH1, TH2) or the DC controller PCB or triac are faulty, causing an error that indicates a temperature sensing issue. The manual's first action is: “Execute service mode '412' (error clear) to clear E001. Open the front door and the top unit, and let the fixing roller cool sufficiently. Turn on the power switch. Is E001 indicated immediately after power-on?”
- Model
- Canon NP7161/NP7160
- Display shows
- E001
- Type
- Error code
- Source
- Manual p. 273
What E001 means
Thermistor (TH1, TH2) p. 273
Common causes
- Thermistor (TH1, TH2) p. 273
- DC controller PCB p. 273
- Triac p. 273
- The thermistor (TH1, TH2) has a short circuit. p. 273
- The triac is faulty. p. 273
- The DC controller PCB is faulty. p. 273
What to do
- Execute service mode '412' (error clear) to clear E001. Open the front door and the top unit, and let the fixing roller cool sufficiently. Turn on the power switch. Is E001 indicated immediately after power-on? p. 273
- Replace the thermistor. p. 273
- Replace the DC controller PCB. p. 273
- End. p. 273
- Check the wiring from the power supply PCB to the DC controller PCB; if normal, replace the DC controller PCB. p. 273
If E001 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Canon service.
This page summarises what the manufacturer’s manual says about E001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Canon. Found a mistake? Report an error.