BC MOD OVERTEMP (0x7183) means the input bridge or brake chopper temperature exceeded the internal alarm limit. The manual's first action is: “Allow the inverter to cool down. Check if the ambient temperature is too high. Inspect the cooling fan for faults. Ensure there is no obstruction to airflow. Verify cabinet size and cooling performance.”
- Model
- ABB ACS850
- Display shows
- BC MOD OVERTEMP (0x7183) (2015)
- Type
- Alarm code
- Source
- Manual p. 284
What 2015 means
BC MOD OVERTEMP (0x7183) p. 284
Common causes
- The input bridge or brake chopper temperature exceeds the internal alarm limit. p. 284
What to do
- Allow the inverter to cool down. Check if the ambient temperature is too high. Inspect the cooling fan for faults. Ensure there is no obstruction to airflow. Verify cabinet size and cooling performance. p. 284
Before you service the product, read the safety instructions in the manual p. 179.
If 2015 is still not resolved
- 请联系当地的 ABB 代表 p. 296 “请联系当地的 ABB 代表”