ABB ACS850 Error 0005: DC UNDERVOLTAGE (0x3220)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Fault code0005

Code 0005 indicates intermediate DC voltage is too low due to a missing phase, a blown fuse, or an internal fault in the rectifier bridge. The manual's first action is: “Check the power supply and the fuse.”

Model
ABB ACS850
Display shows
DC UNDERVOLTAGE (0x3220) (0005)
Type
Fault code
Source
Manual p. 290

What 0005 means

DC UNDERVOLTAGE (0x3220) p. 290

Common causes

  • Intermediate DC voltage is too low due to a missing phase, a blown fuse, or an internal fault in the rectifier bridge. p. 290

What to do

  1. Check the power supply and the fuse. p. 290

Before you service the product, read the safety instructions in the manual p. 179.

If 0005 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”

This page summarises what the manufacturer’s manual says about 0005; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.