ABB ACS850 Error 0064: IGBT OVERLOAD (0x5482)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Fault code0064

IGBT OVERLOAD (0x5482) means the IGBT external case temperature is too high, possibly due to a short circuit in the motor cable. The manual's first action is: “Inspect the motor cable.”

Model
ABB ACS850
Display shows
IGBT OVERLOAD (0x5482) (0064)
Type
Fault code
Source
Manual p. 296

What 0064 means

IGBT OVERLOAD (0x5482) p. 296

Common causes

  • The IGBT external case temperature is too high. This fault protects the IGBT and can be triggered by a short circuit in the motor cable. p. 296

What to do

  1. Inspect the motor cable. p. 296

Before you service the product, read the safety instructions in the manual p. 179.

If 0064 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”