Fault code0061
SPEED FEEDBACK (0x8480) means no speed feedback value is received. The manual's first action is: “Check the parameter settings in parameter group 19 Speed calculation. Inspect the installation of the pulse encoder. See fault 0039 (ENCODER1) for more details.”
- Model
- ABB ACS850
- Display shows
- SPEED FEEDBACK (0x8480) (0061)
- Type
- Fault code
- Source
- Manual p. 295
What 0061 means
SPEED FEEDBACK (0x8480) p. 295
Common causes
- No speed feedback value received. p. 295
What to do
- Check the parameter settings in parameter group 19 Speed calculation. Inspect the installation of the pulse encoder. See fault 0039 (ENCODER1) for more details. p. 295
Before you service the product, read the safety instructions in the manual p. 179.
If 0061 is still not resolved
- 请联系当地的 ABB 代表 p. 296 “请联系当地的 ABB 代表”
This page summarises what the manufacturer’s manual says about 0061; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.