ABB ACS355 Error 2024: ENCODER ERROR 0309 bit 7 (programmable fault function 5003)

ABB ACS355 drive · taken from the manufacturer’s manual, pages cited

Fault code2024

2024 means ENCODER ERROR 0309 bit 7 (programmable fault function 5003), indicating a communication fault between the pulse encoder and pulse encoder interface module or between the module and the drive. The manual's first action is: “Check pulse encoder and its wiring, pulse encoder interface module and its wiring and parameter group 50 ENCODER settings.”

Model
ABB ACS355
Display shows
ENCODER ERROR 0309 bit 7 (programmable fault function 5003) (2024)
Type
Fault code
Source
Manual p. 339

What 2024 means

ENCODER ERROR 0309 bit 7 (programmable fault function 5003) p. 339

Common causes

  • Communication fault between pulse encoder and pulse encoder interface module or between module and drive. p. 339

What to do

  1. Check pulse encoder and its wiring, pulse encoder interface module and its wiring and parameter group 50 ENCODER settings. p. 339

Before you service the product, read the safety instructions in the manual p. 239.

If 2024 is still not resolved

  • contact your local ABB representative p. 19
    “contact your local ABB representative or Authorized Service Center for replacement”

This page summarises what the manufacturer’s manual says about 2024; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.