2024 means ENCODER ERROR 0309 bit 7 (programmable fault function 5003), indicating a communication fault between the pulse encoder and pulse encoder interface module or between the module and the drive. The manual's first action is: “Check pulse encoder and its wiring, pulse encoder interface module and its wiring and parameter group 50 ENCODER settings.”
- Model
- ABB ACS355
- Display shows
- ENCODER ERROR 0309 bit 7 (programmable fault function 5003) (2024)
- Type
- Fault code
- Source
- Manual p. 339
What 2024 means
ENCODER ERROR 0309 bit 7 (programmable fault function 5003) p. 339
Common causes
- Communication fault between pulse encoder and pulse encoder interface module or between module and drive. p. 339
What to do
- Check pulse encoder and its wiring, pulse encoder interface module and its wiring and parameter group 50 ENCODER settings. p. 339
Before you service the product, read the safety instructions in the manual p. 239.
If 2024 is still not resolved
- contact your local ABB representative p. 19 “contact your local ABB representative or Authorized Service Center for replacement”
This page summarises what the manufacturer’s manual says about 2024; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.