Fault code2007
2007 means AI2 LOSS, indicating that analog input AI2 signal has fallen below the limit defined by parameter 3022 AI2 FAULT LIMIT. The manual's first action is: “Check fault function parameter settings.”
- Model
- ABB ACS355
- Display shows
- AI2 LOSS (2007)
- Type
- Fault code
- Source
- Manual p. 337
What 2007 means
AI2 LOSS p. 337
Common causes
- Analog input AI2 signal has fallen below limit defined by parameter 3022 AI2 FAULT LIMIT. p. 337
What to do
- Check fault function parameter settings. p. 337
- Check for proper analog control signal levels. p. 337
- Check connections. p. 337
Before you service the product, read the safety instructions in the manual p. 239.
If 2007 is still not resolved
- contact your local ABB representative p. 19 “contact your local ABB representative or Authorized Service Center for replacement”