ABB ACS355 Error 2002: OVERVOLTAGE

ABB ACS355 drive · taken from the manufacturer’s manual, pages cited

Fault code2002

2002 means OVERVOLTAGE, indicating that the DC overvoltage controller is active. The manual's first action is: “Check deceleration time (2203 and 2206).”

Model
ABB ACS355
Display shows
OVERVOLTAGE (2002)
Type
Fault code
Source
Manual p. 337

What 2002 means

OVERVOLTAGE p. 337

Common causes

  • DC overvoltage controller is active. p. 337

What to do

  1. Check deceleration time (2203 and 2206). p. 337
  2. Check input power line for static or transient overvoltage. p. 337

Before you service the product, read the safety instructions in the manual p. 239.

If 2002 is still not resolved

  • contact your local ABB representative p. 19
    “contact your local ABB representative or Authorized Service Center for replacement”

This page summarises what the manufacturer’s manual says about 2002; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.