Fault code2002
2002 means OVERVOLTAGE, indicating that the DC overvoltage controller is active. The manual's first action is: “Check deceleration time (2203 and 2206).”
- Model
- ABB ACS355
- Display shows
- OVERVOLTAGE (2002)
- Type
- Fault code
- Source
- Manual p. 337
What 2002 means
OVERVOLTAGE p. 337
Common causes
- DC overvoltage controller is active. p. 337
What to do
- Check deceleration time (2203 and 2206). p. 337
- Check input power line for static or transient overvoltage. p. 337
Before you service the product, read the safety instructions in the manual p. 239.
If 2002 is still not resolved
- contact your local ABB representative p. 19 “contact your local ABB representative or Authorized Service Center for replacement”
This page summarises what the manufacturer’s manual says about 2002; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.