0007 means AI1 LOSS, indicating that analog input AI1 signal has fallen below the limit defined by parameter 3021 AI1 FAULT LIMIT and that the drive trips as the motor coasts to stop. The manual's first action is: “Fault limit is defined by parameter 3021 AI1 FAULT LIMIT / 3022 AI2 FAULT LIMIT.”
- Model
- ABB ACS355
- Display shows
- AI1 LOSS (0007)
- Type
- Fault code
- Source
- Manual p. 240
What 0007 means
AI1 LOSS p. 240
Common causes
- The drive trips on fault AI1 LOSS (0007) / AI2 LOSS (0008) and the motor coasts to stop. p. 240
- Analog input AI1 signal has fallen below limit defined by parameter 3021 AI1 FAULT LIMIT. p. 240
What to do
- Fault limit is defined by parameter 3021 AI1 FAULT LIMIT / 3022 AI2 FAULT LIMIT. p. 240
- Check fault function parameter settings. p. 240
- Check for proper analog control signal levels. p. 240
- Check connections. p. 240
Before you service the product, read the safety instructions in the manual p. 239.
If 0007 is still not resolved
- contact your local ABB representative p. 19 “contact your local ABB representative or Authorized Service Center for replacement”