ABB ACS355 Error 0007: AI1 LOSS

ABB ACS355 drive · taken from the manufacturer’s manual, pages cited

Fault code0007

0007 means AI1 LOSS, indicating that analog input AI1 signal has fallen below the limit defined by parameter 3021 AI1 FAULT LIMIT and that the drive trips as the motor coasts to stop. The manual's first action is: “Fault limit is defined by parameter 3021 AI1 FAULT LIMIT / 3022 AI2 FAULT LIMIT.”

Model
ABB ACS355
Display shows
AI1 LOSS (0007)
Type
Fault code
Source
Manual p. 240

What 0007 means

AI1 LOSS p. 240

Common causes

  • The drive trips on fault AI1 LOSS (0007) / AI2 LOSS (0008) and the motor coasts to stop. p. 240
  • Analog input AI1 signal has fallen below limit defined by parameter 3021 AI1 FAULT LIMIT. p. 240

What to do

  1. Fault limit is defined by parameter 3021 AI1 FAULT LIMIT / 3022 AI2 FAULT LIMIT. p. 240
  2. Check fault function parameter settings. p. 240
  3. Check for proper analog control signal levels. p. 240
  4. Check connections. p. 240

Before you service the product, read the safety instructions in the manual p. 239.

If 0007 is still not resolved

  • contact your local ABB representative p. 19
    “contact your local ABB representative or Authorized Service Center for replacement”

This page summarises what the manufacturer’s manual says about 0007; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.