ABB ACS355 Error 0001: OVERCURRENT (2310) 0305 bit 0

ABB ACS355 drive · taken from the manufacturer’s manual, pages cited

Fault code0001

Code 0001 means output current has exceeded the trip level. The manual's first action is: “Check motor load.”

Model
ABB ACS355
Display shows
OVERCURRENT (2310) 0305 bit 0 (0001)
Type
Fault code
Source
Manual p. 344

What 0001 means

OVERCURRENT (2310) 0305 bit 0 p. 344

Common causes

  • Output current has exceeded trip level. p. 344

What to do

  1. Check motor load. p. 344
  2. Check acceleration time (2202 and 2205). p. 344
  3. Check motor and motor cable (including phasing). p. 344
  4. Check ambient conditions. Load capacity decreases if installation site ambient temperature exceeds 40 °C. See section Derating on page 359. p. 344

Before you service the product, read the safety instructions in the manual p. 239.

If 0001 is still not resolved

  • contact your local ABB representative p. 19
    “contact your local ABB representative or Authorized Service Center for replacement”

This page summarises what the manufacturer’s manual says about 0001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.