ZTE MG2639 Manuals

ManualLib has 2 documents for the ZTE MG2639 (Other Electronics): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
ZTE
Model
MG2639
Industry
Electronics
Documents
2
Languages
ZH · EN
Last added
2026-10-24

Start here

ZTE MG2639 GSM Module AT Command Manual

ZTE MG2639 GSM Module AT Command Manual

User Manual 72 pages · 597 KB · ZH

This document serves as the AT Command Manual for the ZTE MG2639 GSM module. It provides comprehensive instructions for system, hardware, software, and test engineers on how to interface with the module via AT commands. The guide covers standard GSM commands as well as specific ZTE proprietary commands for advanced features like TCP/UDP, FTP, and positioning. This manual is written in Chinese.

Read online

ZTE MG2639 specifications

Default Baud Rate115200bps
Data Bits8 bits
Stop Bits1 bit
ParityNone
Hardware Flow ControlNone

Source: ZTE MG2639 GSM Module AT Command Manual

All ZTE MG2639 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the default serial port configuration for the MG2639 module?

The default settings are 8 data bits, 1 stop bit, no parity, no hardware flow control, and a rate of 115200bps.

From: ZTE MG2639 GSM Module AT Command Manual

What does the AT+ZPOWEROFF command do?

The AT+ZPOWEROFF command turns the module off, returning the string 'OK'.

From: ZTE MG2639 GSM Module AT Command Manual

What are the dimensions of the MG2639_V3 module?

The module measures 30.0 mm × 25.0 mm × 3.0 mm.

From: ZTE MG2639_V3 Module Hardware Design User Manual

What is the operating voltage range?

The module operates from 3.4 V to 4.2 V.

From: ZTE MG2639_V3 Module Hardware Design User Manual