Toshiba VF-S15 Manuals

ManualLib has 3 documents for the Toshiba VF-S15 (Motor): 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Brand
Toshiba
Model
VF-S15
Category
Motor
Documents
3
Languages
EN
Last added
2023-10-16

Start here

Toshiba VF-S15 Series Inverter RS485 Communication Instruction Manual

Toshiba VF-S15 Series Inverter RS485 Communication Instruction Manual

User Manual 79 pages · 1 MB · EN

This instruction manual explains the RS485 communication interface function provided for the TOSHIBA TOSVERT VF-S15 series of industrial inverters. It covers data transmission specifications, including baud rates, parity settings, and frame synchronization requirements.

The document details two supported communication protocols: the Toshiba inverter protocol and the Modbus RTU protocol. It provides specific instructions on command formats for reading and writing parameters, monitoring operating status (such as output frequency and current), and controlling operations remotely via a computer or controller.

Read online

Toshiba VF-S15 specifications

Safety FunctionsSTO and SS1
Input Voltage Class3-phase 200V to 240V
Input Voltage Class3-phase 380V to 500V
Input Voltage Class3-phase 525V to 600V
DC Bus Discharge Time15 MINUTES

Source: Toshiba VF-S15 Safety Function Manual

All Toshiba VF-S15 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What safety functions are included in the VF-S15?

The VF-S15 drive incorporates the STO (Safe Torque Off) and SS1 (Safe Stop 1) safety functions.

From: Toshiba VF-S15 Safety Function Manual

How long must one wait before servicing the drive?

You must wait 15 minutes to allow the DC bus capacitors to discharge before servicing.

From: Toshiba VF-S15 Safety Function Manual

How is the acceleration time adjusted?

The acceleration time can be set between 0.0 and 3600 seconds, with a default of 10.0 seconds.

From: Toshiba VF-S15 Inverter Parameter List

What are the available application settings for the VF-S15 inverter?

The inverter supports seven application settings: Initial easy setting, Conveyor, Material handling, Hoisting, Fan, Pump, and Compressor.

From: Toshiba VF-S15 Inverter Parameter List

Which communication protocols are supported by the VF-S15 series?

The inverter supports the Toshiba inverter protocol and the Modbus RTU protocol.

From: Toshiba VF-S15 Series Inverter RS485 Communication Instruction Manual

What is the minimum interval required between data frames?

An interval corresponding to at least 3.5 bytes of data must be placed between frames.

From: Toshiba VF-S15 Series Inverter RS485 Communication Instruction Manual