This document is the instruction manual for the PFE500F series TDK-Lambda power supply unit.
This manual provides safety warnings and operational guidelines for the TDK-Lambda PFE500F series power supply units. It emphasizes precautions against electrical shock, fire hazards, and improper handling. Key safety notes include avoiding use in flammable environments, not modifying the unit, and ensuring proper installation with external fuses. The manual also covers terminal functions, input/output specifications, and environmental operating conditions.
The document includes detailed terminal explanations, connection diagrams, and specifications such as input voltage range (85–265VAC), output voltage adjustment, overcurrent and overvoltage protection, and recommended soldering conditions. It also addresses safety compliance, including SELV (Safety Extra-Low Voltage) requirements and insulation standards.
| Input Voltage Range | 85 to 265VAC |
|---|---|
| Line Frequency Range | 47 to 63Hz |
| Output Voltage Adjustment Range | via TRIM terminal |
| Maximum Output Ripple and Noise | not specified in text |
| Maximum Line Regulation | not specified in text |
| Maximum Load Regulation | not specified in text |
| Over Current Protection (OCP) | not specified in text |
| Over Voltage Protection (OVP) | not specified in text |
| Over Temperature Protection (OTP) | not specified in text |
| Operating Temperature Range | not specified in text |
| Operating Humidity | not specified in text |
| Storage Temperature | not specified in text |
| Storage Humidity | not specified in text |
| Cooling Method | not specified in text |
| Withstand Voltage | not specified in text |
| Insulation Resistance | not specified in text |
| Recommended External Fuse | F15AH, 250V |
| Input Filter | For VCCI-class A |
| Recommended Voltage Rating for Capacitors | 250VAC |
| Inductors L1, L2 | 6mH |
The input voltage range is 85 to 265VAC.
A fast-blown external fuse rated F15AH, 250V is recommended.
The line frequency range is 47 to 63Hz.
The +S and -S terminals are used for remote sensing.