Rotronic HygroClip2 Advanced Manuals

ManualLib has 3 documents for the Rotronic HygroClip2 Advanced (sensor): 3 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 3

Key facts

Model
HygroClip2 Advanced
Category
sensor
Industry
Industrial
Documents
3
Languages
EN
Last added
2023-10-16

Start here

ROTRONIC HygroClip2 ADVANCED Humidity Temperature Probes User Manual

ROTRONIC HygroClip2 ADVANCED Humidity Temperature Probes User Manual

User Manual 35 pages · 821 KB · EN

The HC2A series are digital humidity-temperature probes based on AirChip3000 technology. They feature a UART serial interface and two 0…1 V linear analog output signals. These probes are designed for use with the HygroClip 2 generation of ROTRONIC instruments, including transmitters, data loggers, and hand-helds, but can also function as standalone devices.

Read online

Rotronic HygroClip2 Advanced specifications

Operating humidity0...100 %rh
Operating temperature-50…100 °C
Accuracy±0.8 %rh
Supply voltage3.3…5 VDC
Current consumptionApprox. 5 mA
Cable lengthMax 5 m
Protection ratingIP65
Analog outputs2x 0…1 V
Digital communicationUART

Source: Rotronic HygroClip2 Advanced Short Instruction Manual

All Rotronic HygroClip2 Advanced documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

When should the HygroClip2 Advanced be calibrated?

We recommend a calibration after 1 year of use, depending on the application.

From: Rotronic HygroClip2 Advanced Short Instruction Manual

Which Rotronic products is the HygroClip2 Advanced compatible with?

It is compatible with handhelds of the HP3x family and transmitters of the HF5 and HF8 families.

From: Rotronic HygroClip2 Advanced Short Instruction Manual

How often should the probes be calibrated?

We recommend a calibration after 1 year of use, depending on the application.

From: Rotronic HygroClip2 Advanced Short Instruction Manual

What tools are needed for on-site calibration?

You can perform on-site calibration using the Rotronic SCS humidity standards or the HG2-S humidity generators.

From: Rotronic HygroClip2 Advanced Short Instruction Manual

What is the minimum load requirement for probe voltage outputs?

The manual specifies a section on 'Minimum load requirements for the probe voltage outputs' but does not state the specific value in the provided text.

From: ROTRONIC HygroClip2 ADVANCED Humidity Temperature Probes User Manual

How can the HC2A probes be updated?

The ability to update the AirChip3000 firmware allows the probes to be kept up-to-date regarding future functionality improvements.

From: ROTRONIC HygroClip2 ADVANCED Humidity Temperature Probes User Manual