Recom SIP4 specifications
| Input Voltage Range | +10% |
|---|---|
| Output Voltage Accuracy | +5% |
| Efficiency at Full Load | 70% min. / 80% typ. |
| Isolation Voltage | 2.000VDC min. (tested for 1 second) |
| Operating Temperature Range | -40°C to +85°C |
| Package Type | 7-pin SIP |
All Recom SIP4 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the output voltage of the RE-0505S?
The output voltage is 5V.
What is the efficiency of the RE-0505S at full load?
The efficiency is 70% minimum and 80% typical.
What is the maximum input voltage for the 12V types?
The maximum input voltage for the 12V types is 13.2VDC.
From: RECOM EUROLINE - DC/DC-Converter RxxN RxxO Series 1 Watt DIP8/SIP4 1kVDC Isolation (Single Output)
What is the minimum isolation voltage rating?
The minimum isolation voltage is 1000VDC when flash tested for one second.
From: RECOM EUROLINE - DC/DC-Converter RxxN RxxO Series 1 Watt DIP8/SIP4 1kVDC Isolation (Single Output)
What is the isolation voltage rating?
The converters provide 1kVDC and 2kVDC isolation.
Are custom solutions available?
Yes, the manufacturer states that custom solutions are available.