Key facts
- Brand
- Norac
- Model
- UC7
- Category
- Agricultural Machinery
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2026-10-06
Start here

NORAC UC7 Boom Height Control System Manual
The UC7™ Boom Height Control system improves spraying height accuracy and protects the boom under varied field conditions. This manual explains the system’s purpose, key features, and safety precautions for operators and service personnel.
It covers technical specifications, menu navigation, sensor and valve setup, firmware update procedures, routine maintenance tasks, product registration, and support contact information, helping users install, operate, and maintain the system safely and effectively.
NORAC UC7 specifications
| Supply Voltage (rated) | 12VDC |
|---|---|
| Supply Current (rated) | 10A |
| Hydraulic Pressure (maximum) | 3300 psi |
| Baud Rate | 250 kbps |
| Operating Temperature Range | 0°C to 80°C |
Source: NORAC UC7 Air Boom Height Control System Installation Manual
All NORAC UC7 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the minimum distance the ultrasonic sensor must be from the ground?
The sensor must be at least 9 inches (230 mm) above the ground in its lowest position.
From: NORAC UC7 Air Boom Height Control System Installation Manual
What supply voltage does the system require?
The system is rated for a 12 VDC supply voltage.
From: NORAC UC7 Air Boom Height Control System Installation Manual
How often should the friction pads on the sprayer boom be greased?
Grease the friction pads on the sprayer boom as part of the daily maintenance routine.
What is the part number for the replacement fuse used in the UC7 system?
The replacement fuse part number is NORAC 106676, corresponding to Littelfuse part –0287010.PXCN.
What supply voltage is required for the system?
The system requires a rated supply voltage of 12 VDC.
From: NORAC UC7-BC-JD08 Installation Manual for John Deere 4730/4830 Boom Height Control System
What is the maximum hydraulic pressure the system can handle?
The system is rated for a maximum hydraulic pressure of 3300 psi.
From: NORAC UC7-BC-JD08 Installation Manual for John Deere 4730/4830 Boom Height Control System