NORAC UC7 Manuals

ManualLib has 3 documents for the NORAC UC7 (Agricultural Machinery): 2 installation guides, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Installation Guide 2User Manual 1

Key facts

Brand
Norac
Model
UC7
Industry
Industrial
Documents
3
Languages
EN
Last added
2026-10-06

Start here

NORAC UC7 Boom Height Control System Manual

NORAC UC7 Boom Height Control System Manual

User Manual 38 pages · 2.1 MB · EN

The UC7™ Boom Height Control system improves spraying height accuracy and protects the boom under varied field conditions. This manual explains the system’s purpose, key features, and safety precautions for operators and service personnel.

It covers technical specifications, menu navigation, sensor and valve setup, firmware update procedures, routine maintenance tasks, product registration, and support contact information, helping users install, operate, and maintain the system safely and effectively.

Read online

NORAC UC7 specifications

Supply Voltage (rated)12VDC
Supply Current (rated)10A
Hydraulic Pressure (maximum)3300 psi
Baud Rate250 kbps
Operating Temperature Range0°C to 80°C

Source: NORAC UC7 Air Boom Height Control System Installation Manual

All NORAC UC7 documents by type

Installation Guide 2

Mounting, wiring and first power-up. Read it before the hardware goes in.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the minimum distance the ultrasonic sensor must be from the ground?

The sensor must be at least 9 inches (230 mm) above the ground in its lowest position.

From: NORAC UC7 Air Boom Height Control System Installation Manual

What supply voltage does the system require?

The system is rated for a 12 VDC supply voltage.

From: NORAC UC7 Air Boom Height Control System Installation Manual

How often should the friction pads on the sprayer boom be greased?

Grease the friction pads on the sprayer boom as part of the daily maintenance routine.

From: NORAC UC7 Boom Height Control System Manual

What is the part number for the replacement fuse used in the UC7 system?

The replacement fuse part number is NORAC 106676, corresponding to Littelfuse part –0287010.PXCN.

From: NORAC UC7 Boom Height Control System Manual

What supply voltage is required for the system?

The system requires a rated supply voltage of 12 VDC.

From: NORAC UC7-BC-JD08 Installation Manual for John Deere 4730/4830 Boom Height Control System

What is the maximum hydraulic pressure the system can handle?

The system is rated for a maximum hydraulic pressure of 3300 psi.

From: NORAC UC7-BC-JD08 Installation Manual for John Deere 4730/4830 Boom Height Control System