Key facts
- Brand
- ITech
- Model
- IT8600
- Category
- Other Electronics
- Industry
- Electronics
- Documents
- 2
- Languages
- EN · ZH
- Last added
- 2026-10-27
Start here

Itech IT8600 Series Programmable AC/DC Electronic Load User Manual
This document is the User Manual for the Itech IT8600 series of programmable AC/DC electronic loads. It covers a wide range of models including the IT8615, IT8616, IT8617, IT8624, IT8625, IT8626, IT8627, and IT8628. The manual serves as a comprehensive guide for users to operate, configure, and maintain these electronic load devices safely and effectively. This manual is written in Chinese.
Read onlineITECH IT8600 specifications
| Frequency range | 45 Hz~450 Hz |
|---|---|
| Power range | 0~14.4 kVA (expandable to 43.2kVA) |
| Voltage range | 50~420 Vrms (AC), 15~260 Vrms (DC) |
| Current range | 0~160 Arms |
| Harmonic measurement capacity | up to 50th |
| Communication interfaces | RS232, GPIB, LAN, USB |
All ITECH IT8600 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What frequency range does the IT8600 support?
The instrument supports an adjustable frequency from 45 Hz to 450 Hz.
What types of devices can the IT8600 be used for testing?
It is designed for testing UPS, inverters, frequency converters, generators, AC power supplies, and electronic components.
What is the operating temperature range for this electronic load?
The device operates within a temperature range of 0° C to 40° C.
From: Itech IT8600 Series Programmable AC/DC Electronic Load User Manual
At what temperature does the cooling fan start running?
The fan starts when the heatsink temperature reaches 40° C.
From: Itech IT8600 Series Programmable AC/DC Electronic Load User Manual