User manual for the FLIR DM92 True RMS Industrial Multimeter covering safety, meter description, operation, maintenance, and specifications.
The FLIR DM92 True RMS Industrial Multimeter user manual describes the meter's functions, operation, and maintenance. The introduction lists key features such as a 4000/40 000-count dual display, auto AC/DC selection in voltage and current modes, variable-frequency drive mode with low-pass filter, 0.05% DCV accuracy, Low-Z measurement, auto hold, peak hold, dB/dBm measurement, a 99-record data memory, and CAT IV-600 V / CAT III-1000 V safety rating.
The manual explains function switch positions, function buttons, display icons, and measurement procedures for voltage, resistance, continuity, diode, capacitance, Type K temperature, and current. It also covers extended functionality, hold modes, cleaning and storage, battery and fuse replacement, general specifications, electrical range specifications, technical support, and warranties.
| Maximum voltage | 1000 V DC or 1000 V AC RMS |
|---|---|
| Display count | 4000 / 40 000 |
| Measuring rate | 10 samples per second |
| Power requirements | 6 x 1.5 V AAA alkaline batteries |
| Battery life | Approx. 100 hours with batteries (backlight and worklight off) |
| Auto power off | Default 10 minutes |
| Calibration cycle | Once per year |
| Safety | IEC 61010 -1 CAT IV -600 V, CAT III -1000V, IEC 61010 -2-033 |
| Drop protection | 6.6’ (2 m) |
The meter has a safety category rating of CAT IV-600 V and CAT III-1000 V.
It uses six 1.5 V AAA alkaline batteries.
Battery life is approximately 100 hours with the backlight and work light off.
The default auto power off time is 10 minutes.