Endress+Hauser Liquicap M FMI51/FMI52 Capacitive Level Measuring Instrument Technical Information

Endress+Hauser Liquicap M FMI51/FMI52 is a capacitive level measuring instrument for continuous level measurement, with installation, operating conditions…


Endress+Hauser Liquicap M FMI51/FMI52 Capacitive Level Measuring Instrument Technical Information - cover page
Brand
Endress+Hauser
Category
Monitoring Equipment
Document type
Product Leaflet
Language
Chinese
Pages
36
File format
PDF
File size
2.2 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
177258376A983014A34860BA59951267

About this manual

Liquicap M FMI51/FMI52 is an integrated transmitter for continuous level measurement. Its sensor construction is suitable for vacuum service and overpressure up to 100 bar, with materials rated for -80 to +200 °C; for media with conductivity of 100 μS/cm or higher, no calibration is required.

This technical information covers function and system design, measuring principle and system, Fieldgate integration, installation and ambient/process operating conditions, mechanical construction, sensor data, input/output, power supply, electrical connection, performance characteristics, human interface, certificates and approvals, ordering information, accessories and spare parts. This manual is written in Chinese.

What's inside

  • Function and system design
  • Measuring principle
  • Measuring system
  • System integration via Fieldgate
  • Installation conditions
  • Ambient conditions
  • Process conditions
  • Mechanical construction
  • Sensor technical data
  • Performance characteristics

Specifications

ApplicationContinuous level measurement
Material operating temperature range-80 to +200 °C
Overpressure capabilityUp to 100 bar
Vacuum serviceSuitable for vacuum measurement
Conductivity for calibration-free operation100 μS/cm or higher
Ambient temperature range with F16 housing-40 to +70 °C
Climate classDIN EN 60068-2-38/IEC 68-2-38, Z/AD test
Vibration20 Hz to 2000 Hz, 0.01 g²/Hz
Shock30 g acceleration
EMC emissionsEN 61326, Class B
Fault current (FEI50H)22 mA

Frequently asked questions

What is the Liquicap M FMI51/FMI52 used for?

It is an integrated transmitter for continuous level measurement.

Does it require calibration for conductive media?

No calibration is required when the medium conductivity is 100 μS/cm or higher.

Can it measure interface layers?

Yes, it can perform interface measurement.

What ambient temperature range is supported?

The range is -50 to +70 °C, or -40 to +70 °C with an F16 housing.