Emerson NLP110 Series Power Module Datasheet
The NLP110 Series power modules from Emerson provide single or triple output configurations with up to 10.5 A per output at 3.3 V, 5 V or 12 V. They are designed for business‑critical continuity applications, meet EN61000‑3‑2, EN55022, EN55011 and other international standards, and include over‑voltage and short‑circuit protection.
The modules operate from a universal input voltage of 90‑264 Vac, deliver total power between 80 W and 110 W, and feature thermal management options such as natural convection and forced‑air cooling. Mechanical dimensions, connector types, and compliance information are detailed for integration into 1U equipment.
Artesyn NLP110 specifications
| Input voltage range | 90‑264 Vac |
|---|---|
| Total power | 80‑110 W |
| Output regulation | ±2.0 % (main), ±5.0 % (auxiliary) |
| Efficiency (80 W load) | ≥75 % |
| Weight | 283 g (10 oz) |
| MTBF | 220,000 hours (min) |
All Artesyn NLP110 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the input voltage range for the NLP110 Series?
The modules accept a universal input voltage from 90 Vac to 264 Vac.
What is the maximum continuous output power for single‑output units?
Single‑output units are limited to a maximum continuous output power of 75 W (up to 110 W for higher‑rated models).
What input voltage range does the NLP110 support?
The NLP110 operates from 90 Vac to 264 Vac.
From: Artesyn NLP110 Medical Series Single and Triple Output Datasheet
How many output configurations are available?
It is offered in single‑output and triple‑output versions.
From: Artesyn NLP110 Medical Series Single and Triple Output Datasheet