Zhenjiang JN15-12/31.5 Indoor High-Voltage Grounding Switch Installation and Use Manual

Installation and use manual for the Zhenjiang JN15-12/31.5 indoor high-voltage grounding switch, covering parameters, structure, installation and maintenance.


Zhenjiang JN15-12/31.5 Indoor High-Voltage Grounding Switch Installation and Use Manual - cover page
Brand
镇江市电工器材厂
Category
Switch disconnector
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
165 KB
Published
28 February, 2012
Updated
20 November, 2026
MD5 checksum
01B484C930174681FC84CEC1DBAAE3C6

About this manual

This manual covers the JN15-12/31.5 indoor high-voltage grounding switch made by Zhenjiang City Electrical Equipment Factory. After full testing its performance meets GB 1985-89 "AC High-Voltage Disconnectors and Earthing Switches" and IEC 129; it is intended for three-phase AC 50 Hz power systems with rated voltage of 12 kV and below, can be matched with various high-voltage switchgear for earthing protection, and can be fitted with a voltage indicating device.

The manual states the service environment conditions (ambient temperature upper limit +40 °C, lower limit -10 °C, storage/transport at -25 °C permitted; altitude not over 1000 m; relative humidity daily average not greater than 95%), explains the model designation, lists technical parameters such as rated voltage 12 kV, 4 s thermal stability current 1.5 kA, dynamic stability current 80 kA peak and closing current 80 kA peak, and describes the structure and working principle, installation and adjustment, operation and maintenance, packing, transport and storage, and ordering information. This manual is written in Chinese.

What's inside

  • Product Overview
  • Service Environment Conditions
  • Model Designation
  • Technical Parameters
  • Structure and Working Principle
  • Installation and Adjustment
  • Operation and Maintenance
  • Packing, Transport and Storage
  • Ordering Information

Specifications

Rated voltage12 kV
4 s thermal stability current (RMS)1.5 kA
Dynamic stability current (peak)80 kA
Closing current (peak)80 kA
Lightning impulse withstand voltage75 kV
Main circuit 1 min power-frequency withstand voltage42 kV
Secondary circuit 1 min power-frequency withstand voltage2 kV
Ambient temperatureUpper limit +40 °C, lower limit -10 °C; storage/transport permitted at -25 °C
AltitudeNot exceeding 1000 m
Relative humidityDaily average not greater than 95%

Frequently asked questions

Which standards does the JN15-12/31.5 comply with?

Its performance meets GB 1985-89 "AC High-Voltage Disconnectors and Earthing Switches" and IEC 129.

What are the rated voltage and frequency of the JN15-12/31.5?

It is for three-phase AC 50 Hz systems with a rated voltage of 12 kV and below.

Can the switch be fitted with a voltage display device?

Yes, it can be provided with a voltage indicating device.

What phase-to-phase distances are available?

275, 250, 230 and 210 mm; other spacing and installation dimensions can be ordered on request.