WIKA CPT6100 Barometric Pressure Transducer Data Sheet

WIKA CPT6100 barometric pressure transducer data sheet covering accuracy, range, communication, specifications, and ordering information.


WIKA CPT6100 Barometric Pressure Transducer Data Sheet - cover page
Brand
WIKA
Category
pressure transmitters
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
482 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1191F5F648601385F18E72F8CFE5B23E

About this manual

The WIKA CPT6100 is a barometric pressure transducer for high-accuracy barometric pressure measurement. The data sheet lists applications such as OEM devices, test and calibration stands, and laboratory barometric standards, along with special features including 0.010% R accuracy, an 8 to 17 psia range, and RS-232 or RS-485 communication.

The document provides specifications including measuring range, accuracy, pressure units, display resolution, pressure connections, voltage supply, ambient conditions, communication settings, certificates, ordering information, scope of delivery, options, and accessories. It also includes dimensional drawings and notes on zero and span adjustment through the serial interface.

What's inside

  • Applications
  • Special Features
  • Description
  • Functional Flexibility
  • Specifications
  • Communication Interface
  • Ordering Information
  • Scope of Delivery
  • Options
  • Accessories

Specifications

Measuring range552 ... 1,172 mbar abs. (8 ... 17 psi abs.)
Accuracy0.01 % of reading
Precision0.004 % FS
Calibration interval180 days
Power supply+12 VDC ± 10%, 55 mA max
Compensated temperature range15 ... 45 °C (59 ... 113 °F)
Weight505 g (1.11 lbs.)
Communication interfaceRS-232 or RS-485
Baud rate9,600, 19,200, 38,400 or 57,600 baud
Pressure connection7/16-20 SAE for pressure and reference port
Display resolutionCPT6100: 6 significant figures
Warm-up timeapprox. 15 min up to the specified accuracy

Frequently asked questions

What is the measuring range of the WIKA CPT6100?

The CPT6100 covers 552 ... 1,172 mbar abs. (8 ... 17 psi abs.).

What communication interfaces does the CPT6100 support?

It supports RS-232 or RS-485 communication.

What is the recommended calibration interval?

The recommended calibration interval is 180 days.

What is the warm-up time for specified accuracy?

Warm-up time is approximately 15 minutes up to the specified accuracy.

Download PDF (482 KB)