This document serves as a comprehensive cable sizing guide for VIDEX security products, providing minimum cable requirements in mm² for various distances. It covers a wide range of systems including audio telephones, videophones, VPROX and O2LA proximity systems, CODIX data buses, and Sentry digital systems. The guide details specific core sizes for connections between door panels, readers, and control units.

What's inside

  • AWG to mm² Conversion
  • Audio Telephone Connections
  • Videophone Connections
  • VPROX Proximity Systems
  • O2LA Proximity Systems
  • CODIX Data Bus
  • ESK and VK6N Systems
  • CVK6N and CSMVK Systems
  • Power Supply Connections
  • Maximum Resistance Limits

Specifications

Maximum distance between reader and CPU (VPROX)200m
Maximum acceptable resistance for VPROX terminals10 Ω
Maximum distance between O2LA readers and control unit50m
Maximum distance between O2LA CPUs1km
Recommended cable size for VPROX power supply1.0mm²
Maximum acceptable resistance for power supply cables3 Ω

Frequently asked questions

What is the recommended cable type for VIDEX installations?

A popular cable type to use would be CW1308 or an equivalent twisted pair telephone cable.

What is the minimum cable size for VPROX reader connections?

The minimum cable size for VPROX reader connections is 0.25mm².

How far can an O2LA reader be from the control unit?

The readers can be a maximum of 50m from the control unit.