VIDEX Security cable sizing guide for audio, video, and proximity systems including AWG to mm² conversion and resistance limits.
This document serves as a comprehensive cable sizing guide for VIDEX security products, providing minimum cable requirements in mm² for various distances. It covers a wide range of systems including audio telephones, videophones, VPROX and O2LA proximity systems, CODIX data buses, and Sentry digital systems. The guide details specific core sizes for connections between door panels, readers, and control units.
| Maximum distance between reader and CPU (VPROX) | 200m |
|---|---|
| Maximum acceptable resistance for VPROX terminals | 10 Ω |
| Maximum distance between O2LA readers and control unit | 50m |
| Maximum distance between O2LA CPUs | 1km |
| Recommended cable size for VPROX power supply | 1.0mm² |
| Maximum acceptable resistance for power supply cables | 3 Ω |
A popular cable type to use would be CW1308 or an equivalent twisted pair telephone cable.
The minimum cable size for VPROX reader connections is 0.25mm².
The readers can be a maximum of 50m from the control unit.